5915 Star Lane

Houston, Texas 77057

(713) 680-9425

 

 

 

 

 

  

  TESTING FORMS USED BY PRECISION PETROLEUM LABS
   

 

 

 

PENDING DATA

 

Summary Guide to Lab Requirements:

 

Virgin Contaminants
 
Contaminant
NH
NY
Gasoline / Jet Fuel - TPH-GRO
- Total Lead 1
- TPH-GRO 4
- Total Lead 1
#2 Fuel Oil Diesel - TPH-DRO 2
- Total Lead 1
- TPH-DRO 3,4
- Total Lead 1
#4, 6 Fuel Oil

 
-TPH-DRO2
-Total lead1
-Total VOCs9
-Total SVOCs9
- TPH-DRO 3,4
- Total Lead 1

Mixed Fuels
(fuel oil /gas)
- TPH-DRO/GRO
- Total Lead 1
- TPH-DRO/GRO 4
- Total Lead 1

Animal, Vegetable, Tall oil
- TPH by 8100 or
  8015DRO
- TPH by 8100 or
  8015DRO 4
Petroleum Solvents - TPH by 8100 or 8015DRO
- Total VOC’s
- Total SVOC’s
- Ignitibility/Flash
- TPH by 8100 or 8015DRO 4
- Total VOC’s 4
- Total SVOC’s 4

Waxes and Petrolatum
- TPH by 8100 or 8015DRO
- Total VOC’s
- Total SVOC’s
- TPH by 8100 or 8015DRO 4
- Total VOC’s 4
- Total SVOC’s 4


 

Non-Virgin Contaminants
 
Contaminant
NH
NY
Used Oils, Greases, Lubricants - TPH by 8100 or 8015DRO
- Total VOC’s
- Total RCRA 8 metals
- TPH by 8100 or 8015DRO
- Total VOC’s
- Total RCRA 8 metals
Used Animal, Vegetable, Tall oils - TPH by 8100 or 8015DRO
- Total VOC’s
- Total SVOC’s
- Total RCRA 8 metals
- TPH by 8100 or 8015DRO

Petroleum Solvents (used)
- TPH by 8100 or 8015DRO
- Total VOC’s
- Total SVOC’s
- Total RCRA 8 metals
- Ignitibility/Flash
- TPH by 8100 or 8015DRO
- Total VOC’s
- Total SVOC’s
- Total RCRA 8 metals
- Ignitibility/Flash


 

Coal Tars / PCBS / Urban Fill
 
Contaminant
NH
NY

Coal tars, coal, pitch, tar, asphalt emulsion
- TPH by 8100 or   8015DRO
- Total VOC’s
- Total SVOC’s
- Total RCRA 8 metals
- Total Cyanide / %Sulfur
  ( Non-Reactive
- TPH by 8100 or
  8015DRO
- Total VOC’s
- Total SVOC’s
- Total RCRA 8 metals
- Total Cyanide / %Sulfur
- Total BTU
- Total PCBs
Urban Fill - TPH by 8100 or   8015DRO
- Total VOC’s
- Total PAH's
- Total RCRA 8 metals
- PCBs
- TPH by 8100 or   8015DRO
- Total VOC’s
- Total SVOC’s
- Total RCRA 8 metals
- PCBs
Electrical oils - TPH-DRO
- Total PCBs
- TPH-DRO
- Total PCBs,

Transformer Oils
- TPH-DRO
- Total PCBs
- TPH-DRO
- Total PCBs
Dredge 6 - TPH by 8100 or   8015DRO
- Total VOC’s
- Total PAH's
- Total RCRA 8 metals
- PCBs
- Total Cyanide / %Sulfur   5
- TPH by 8100 or   8015DRO
- Total VOC’s
- Total SVOC’s
- Total RCRA 8 metals
- Total Cyanide /
  %Sulfur5
- Total BTU 5
- Total PCBs

Notes:

1) Total lead required for urban areas, and historical gas releases where lead may have been present.

2) (NH Facility): Virgin Fuel Releases less than 50 tons do not require sampling as long as the generator certifies that there are no other contaminants present.

3) (NY Facility): Certified residential sites under 150 tons require in-house TPH testing only.

4) (NY Facility): NYSDEC directed virgin spill cleanups require in-house TPH when
certified virgin and characterization is waived by a NYSDEC Spill Representative.

5) Required if coal tar is present.

6) Dredged soil must be sampled prior to mixing or drying. Chain of Custody must reflect this and be included with all lab results.

7) Any soils containing a listed hazardous waste, may be accepted, at the discretion of the facility when accompanied with a State Certified “contained-out” determination.

8) At the discretion of the facility, additional lab may be required for project acceptance.

9) One sample required for each 500 tons.


Back to Top

4. Acceptable Lab Methods:

All analysis is required to be conducted by a State Certified lab using SW-846 Methods*.

Analysis
Method
TPH
GC/FID
Total VOC's
Method 8260
Total SVOC's / PAH
Method 8270
RCRA 8 Metals
Method 6010B
( Arsenic, Barium, Cadmium,
Chromium Total, Lead,
Selenium, Silver and Mercury (7471A) )
PCBs
Method 8082
Ignitibility
Method 1010
Total Cyanide
Method 9010
Total Sulfur
EPA D129-64
BTU
ASTM-D240-87


 

Back to Top

5. Sampling Frequency:

Sample
ESMI of NH
Sum of Tons NH
ESMI of NY
Sum of Tons NY
1st Sample
200 Tons 200 150 Tons 150
2nd Sample
200 Tons 400 150 Tons 300
3rd Sample
200 Tons 600 450 Tons 750
4th Sample
200 Tons 800 750 Tons 1500
5th Sample +
Each Sample is equal to 200 tons, up to 4000 tons (20 samples) then 500 tons after that. 1000 and up Each additional sample is worth 750 tons 2250


 

Back to Top

Scheduling soil to the facility:

Once the waste has been properly profiled and laboratory data has been reviewed and approved by the Precision Petroleum Labs compliance department, the job can be scheduled through the sales department. We encourage customers to communicate their needs as far out as possible and keep us informed of any changes. We want your project to run as smoothly as you do, the more involved we get in the work schedule the better we can serve your needs.

Back to Top

Shipping:

Required Shipping Papers
State Shipping Papers
New Hampshire Straight BOL or Non-hazardous waste manifest
Massachusetts Mass BOL, MSR or Non-hazardous waste manifest
New York Straight BOL or Non-hazardous waste manifest
Vermont Straight BOL or Non-hazardous waste manifest
Maine Straight BOL or Non-hazardous waste manifest
Connecticut Straight BOL or Non-hazardous waste manifest

(Note: Some special situations may exist where other documents are required on a case by case basis)

 